• New method added: RunFinalTestAsync() - Performs final mobile tests including SSH verification of setup files
• Calls SSH.MobiletxtCheck() to verify /home/mav/Mobile-Setup-configuration-marker.txt exists on device
• Updates UI with "MobileSetup.sh" pass/fail status
• Mobile Tests/Mobile API.cs (New File Created)
New Method Added: MobiletxtCheck(string IPAddress) - Boolean method to verify setup marker file
• Checks if /home/mav/Mobile-Setup-configuration-marker.txt exists on device via SSH
• Returns exit status 0 (true) if file exists, false otherwise
• Used in RunFinalTestAsync() for setup verification
• Introduced new Mobile API.cs module
• Encapsulates firmware checks, day/night mode switching, and snapshot operations
• Methods: CheckFirmwareAsync(), SetDayModeAsync(), SetNightModeAsync()
• Improves code maintainability and separates API logic from test execution
UI Components
• DayImgPcbx PictureBox: Displays day snapshot
• NightImgPcbx PictureBox: Displays night snapshot
• DayImage Label: Shows day luminance percentage
• NightImage Label: Shows night luminance percentage
Features Implemented
• Luminance-based validation: Uses ImageProcessing.GetMeanLuminance() to quantitatively analyze day and night snapshots
• Validation logic: Day luminance must exceed night luminance to pass the test
• Real-time luminance display: Appends calculated luminance percentages (0-100%) to day and night image labels
• Enhanced error reporting: Logs detailed luminance values when test fails for debugging purposes
• Captures day mode snapshot → Analyzes luminance
• Captures night mode snapshot → Analyzes luminance
• Compares values and updates UI labels with percentages
• Result: "Day/Night Mode = Passed" (green) or "Day/Night Mode = Failed" (red) with error details